Product Details:
|
Nominal Capacity: | / | Nominal Voltage: | / |
---|---|---|---|
Internal Impedence: | / | Operating Votage: | / |
Dimension: | / | Battery Weight: | / |
Features:
Rated power operation the maximum temperature of the battery is less than 40℃
EMS,hybrid inverter and BMS integrated technology, power supply redundancy design, support black start function,Off grid operation, etc
Suitable for high rate cyclic charging and discharging scenarios
Lithium Iron Phosphate (LFP) Battery, The battery pack and system adopt an aerosol fire extinguishing solution
Combustible gas, smoke and temperature detection, system active exhaust, and fire alarm
Supports battery expansion, with a maximum capacity of 360KWh
Specifications:
Model | GE-F60 |
System Specification | |
Model | GE-F60-V1 |
AC Output Frequency and Voltage | 50/60Hz; 3L/N/PE 220/380, 230/400Vac |
Grid Type | Three phase |
Energy Configuration (kWh) | 61.4 |
Dimension (W x D x H,mm) | 735x1050x2250(no contain inverter) |
Weight Appr. (kg) | 950(battery)+80(inverter) |
AC Output Rated Current (A) | 75.8 |
Battery Operating Voltage (V) | 500 ~ 700 |
Max. charging/discharging efficiency | 91% |
Battery Chemistry | LiFePO4 |
IP Rating of Enclosure | IP55 |
Installation Style | Floor-Mounted |
Warranty | 10 years |
Inverter Technical Specification | |
Max. PV Input Power (W) | 65000 |
Max. PV Input Current (A) | 36+36+36+36 |
Rated PV Input Voltage (Vdc) | 600 |
Start Up DC Voltage (Vdc) | 180 |
MPPT Voltage Range (Vdc) | 150-850 |
Max. PV Short-circuit Current (A) | 55+55+55+55 |
Number of MPPT | 4 |
Peak Power (off grid) | 1.5 time of rated power, 10s |
Power Factor | 0.8 leading to 0.8 lagging |
THD | <3% |
DC injection current (mA) | <0.5%ln |
Display | LCD |
Operating Temperature Range (℃) | -40~60( >45℃ derating) |
Relative Humidity | 15% ~ 85% (No Condensing) |
Dimension (W x D x H,mm) | 527x294x894 |
Inverter Communication | CAN,RS485,WIFI,ETH |
Max. Efficiency | 97.6% |
MPPT Efficiency | 99.9% |
Battery Technical Specification | |
Battery Module Nominal Voltage (V) | 51.2 |
Battery Module Energy (kWh) | 5.12 |
BMS Communication | CAN |
Battery Module Dimension(W*D*H mm) | 440x570x133 |
Battery Module Weight (kg) | 44 |
Operating Temperature Range | Charge: 0~55℃ / Discharge: -20℃~55℃ |
Cycle Life | ≥6000(@25℃±2℃,0.5C/0.5C,70%EOL) |
Battery Module Certification | CE, IEC62619, IEC62040, UN38.3 |
Safety EMC / Standard: IEC/EN 62109-1,IEC/EN 62109-2,IEC/EN 61000-6-1, IEC/EN 61000-6-2,IEC/EN 61000-6-3,IEC/EN 61000-6-4
Grid Regulation: VDE4105,IEC61727/62116,VDE0126,AS4777.2,CEI0 21,EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/ NBR16150
Product expansion:
Product introduce:
①Air conditioner | Cooling the ESS system |
②Smoke detector | A device used to detect smoke in a fire and sound an alarm when smoke is detected. |
③Heat detector | A device used to measure temperature and sound an alarm if it detects excessive temperature. |
④Travel switch | Check whether the ESS system door is closed. |
⑤Inverter | A device that converts direct current generated by a battery into alternating current. |
⑥Aerosol fire extinguishing device | When the ESS is detected to be on fire, aerosol is emitted to extinguish the fire. |
①Fan | Emission of combustible gas |
②Combustible gas sensor | Detect combustible gases |
③Serial relay | Control system |
④Terminal line | For connecting cables |
⑤Switching Mode Power Supply | Power source |
⑥Temperature and humidity sensor | Used to measure ambient temperature and humidity |
⑦Miniature circuit breaker | Controlled power-on and power-off |
⑧Relay | Automatic regulation, safety protection, conversion circuit |
⑨Water immersion sensor | Check the ESS for water leakage |
⑩Terminal line | Connect external cables |
①Aerosol fire extinguishing device | When the pack is detected to be on fire, aerosol is emitted to extinguish the fire |
②Battery module | Provides electrical energy storage and output |
③CCS | Cells Contact System |
④Air inlet | Cold air inlet |
⑤Battery negative- | / |
⑥Battery positive+ | / |
⑦Fan | Promote internal and external air flow |
⑧BMU | Battery monitoring |
①B- | Connection position of the common negative pole of the battery |
②B+ | Connection position of the common positive pole of the battery |
③Air switch | Used to manually control the connection between the battery rack and external devices |
④ALRM light indicator | Battery system fault alarm indicator |
⑤HV light indicator | High-voltage hazard indicator |
⑥PCS- | Connection position of PCS negative pole |
⑦PCS+ | Connection position of PCS positive pole |
⑧USB | BMS upgrade interface and storage expansion interface |
⑨OUT COM | Connection position with next HVB-100A 750V communication output |
⑩IN COM | Connection position with previous HVB-100A750V communication input |
⑪PCS COM | Communication interface with charging and discharging equipment |
⑫START | A start switch of 12VDC power inside the high-voltage control box |
⑬COMM1 | Communicative connection with the cabinet |
⑭COMM2 | Communicative connection with the first battery module; and providing 12VDC power for the first battery module. |